W Tombling Ltd - activair
 about W Tombling Ltd - activair How to contact us Please send me a quotation sign up for our free activair newsletter

Heaters

Heater Homepage
High air volume fan heaters
Wall mounted electric heaters
Portable heaters
- 3 phase
Portable electric heater
- single phase
Portable radiant heater
Wall mounted radiant heaters
Portable dehumidifier
Benefits
Typical Applications
Heat Loss Calculation
Controlling Our Heaters
Installing Our Heaters
Accessories
Commercial Buildings
Green Houses
Condensation Control
Heater FAQ's
spacer

Search this site:


Using : 
All Words 
Any Words
Phrase

W. Tombling Ltd.

Wembley House
Dozens Bank
West Pinchbeck
Spalding
Lincolnshire
PE11 3ND
U.K.


industrial fan heatershigh temperature industrial fan heaters --------------

High temperature industrial fan heaters

floor standing high temperature fan heater

Activair high temperature industrial fan heaters are designed for continuous operation at up to 70C, and are intended for use in industrial drying, curing and space heating applications.

They are supplied with a dual purpose stand/bracket, which allows them to be wall mounted or stood on the floor.

Activair high temperature industrial fan heaters are manufactured from corrosion resistant stainless steel, (casing - SS2320, grilles and floor stand - SS2333). They are protected to IP44, and are approved for use in damp environments.

Features of Activair high temperature industrial fan heaters

Activair high temperature fan heaters are available in 6kW and 9kW versions for use with 400V3N phase electrical supplies.

Activair high temperature industrial heaters have been designed to provide years of trouble free operation: wall mounting high temperature heater

Fan motors - maintenance free and totally enclosed
Elements – long life encapsulated stainless steel tubular elements
Overheat protection - built in safety device with manual reset
Stainless steel casing - corrosion resistant

High temperature industrial fan heaters - controls

Activair high temperature industrial fan heaters are completely self contained, each heater contains:

Capillary thermostat - adjustable between 0 and 70C
Safety overheat cutout - with manual reset
Output selector - full heat, half heat, and fan only
floor standing high temperature fan heater

An external 0-70C thermostat (RTH) is available separately, it is intended for use when the heater is wall mounted out of reach. Protected to IP44 and measuring 140 x 175 x 100mm, it overrides the built in thermostat.

The RTH external thermostat MUST be installed in the same room as the heater it controls.

Activair high temperature industrial fan heaters
Specification
Model   H6 H9
Element rating kW 6 9
  Btu/hr 20460 30690
Voltage V 400-3ph-N-E 400-3ph-N-E
Conection   5 core bare wire 5 core bare wire
Power stages kW 0 - 3 - 6 0 - 4.5 - 9
Maximum phase current A 8.9 13.2
Noise dBA 53 55
Air volume m3/h 1000 1000
Max. temperature rise C 17 25
Built in thermostat C 0 - 70 0 - 70
Protection class   IP 44 IP 44
Weight kg 19 19
Width mm 375 375
Height mm 445 455
Depth mm 295 295
Price ex. delivery & VAT   £1799.99 £1999.99
Price inc. delivery & VAT   quote for high temperature industrial heaters quote for high temperature industrial heaters

Activair high temperature industrial fan heaters - documents

Activair high temperature industrial fan heaters - approvals

Activair high temperature industrial fan heaters have been tested for safety in accordance with the LVD directive, and for electro-magnetic interference in accordance with the EMC directive as follows:

EMC
Directive 89/336EEC Article 10.2
EN 60335-1:1994, A1, A2, A11-16
EN 60335-2-30:1997, A1
EN 50014:1993
EN 50081-1:1992
EN50081-2:1993
EN 61000-3-2:1995, A12
EN 61000-3-3:1995
EN 55104:1995

LVD
EN 60335-1:1994, A1, A2, A11-16
EN 60335-2-30:1997, A1
SEMKO 111FF-1987, EMKO-TUB (61) N289/90




 

GS
EN 60335-1:1994, A11:95, A12, A1:96, A13, A14:98, A15, A2:00, A16:01
EN 60335-2-30:1997, A1:00

Activair high temperature industrial fan heater approvals

Activair high temperature industrial fan heaters are CE marked.

Frequently asked questions

Can these heaters be used in wet rooms?

The heaters are rated to IP44, meaning they are protected from from splashing water coming from any direction making them suitable for areas with exposure to moderate moisture for example bathrooms and sheltered outdoor areas. They must not be used in high moisture zones, or where jets of water are present, for example sauna's, wash down rooms, laundries, etc.

Can I install the RTH external control in another room?

No, the RTH must be mounted in the same room as the heater it controls.

How do I control the heater from another room?

You will need a thermostat with a remote sensor, capable of measuring up to a maximum of 70C. It will also need to be rated to the full phase current of the heater. With reference to the wiring wiagram it should replace the dotted box marked 'External control'.

Do you supply such a thermostat?

We do not. Every customer's requirements are different, some want devices with timers, digital displays, or to be suitable for building into control panels. So we leave to the customer to source a device that meets their needs.

Can I control the heater remotely simply by switching the supply?

No, the fan needs to run continuously. Switching the supply will disconnect the supply to the fan, causing the protective over heat cut out to operate. You need a remote thermostat as described above.

How long will it take for the room to reach the required temperature?

That depends on the heatloss of the room being heated and the air changes at the required final temperature. It is the responsibility of the system designer or specifier to make sure the heater(s) selected have a big enough output.

Activair high temperature industrial fan heaters - 1 year guarantee

Activair high temperature industrial fan heaters are manufactured to the highest standards, and we are confident that they are totally reliable. However, in the unlikely event a fault may occur, they have a full 1 year return to base parts and labour guarantee.

Choosing the correct size of heateron line calculator

Before selecting a fan heater it is important to carry out a heatloss calculation to determine the size required. See heater size calculations for further details, or use our on line calculator.

Electricity supply requirements for Activair high temperature industrial fan heaters

Activair high temperature fan heaters are designed for 400V 3 phase and neutral 50Hz electricity supplies.

They are suitable for use in the UK, most of Europe, Eastern Europe and the Middle East, but not the United States.

Activair high temperature industrial fan heaters are designed for continuous operation at up to 70C. Their robust construction, long life elements and totally sealed motor guarantee many years of trouble free operation at high temperature.